CCA, Ah and reserve capacity: the three numbers decoded

Every label carries three figures that measure three different things. Buying the wrong one for your application is how people end up with a battery that "should" work and doesn't.

Cold cranking amps (CCA)

CCA is the current a battery can deliver for 30 seconds at 0°F (−18°C) while staying above 7.2V. It measures starting ability in cold weather and nothing else. A higher CCA figure does not mean more usable energy — it usually means thinner plates, which are less tolerant of deep discharge.

Related: CA and MCA (marine cranking amps) are the same test at 32°F (0°C), so MCA numbers look roughly 20-30% higher than CCA for the same battery. Comparing a CCA figure with an MCA figure is one of the most common spec-sheet errors.

Amp-hours (Ah)

Ah is capacity: the current a battery can supply for 20 hours at 77°F before falling to 10.5V, for a 12V battery. A 100Ah battery can nominally deliver 5A for 20 hours. Real capacity varies with discharge rate — pulling 50A from the same battery gets you far less than 2 hours — which is why lithium, with a flatter discharge curve, appears to out-perform its rating in practice.

Reserve capacity (RC)

RC is minutes at 25A before dropping below 10.5V. It is the most honest number for an application like a boat with a failed alternator, or a car with a failing alternator limping home.

FigureMeasuresMatters most for
CCA30s burst at 0°FStarting engines in cold weather
Ah (20hr)Slow capacityHouse banks, golf carts, solar
RCMinutes at 25ABackup / limp-home capacity
WhEnergy (Ah × V)Comparing across voltages

The four chemistries in one paragraph each

Flooded lead-acid

Cheapest per amp-hour, tolerant of abuse, needs watering and venting, and must not be discharged below about half. Best value where weight and maintenance do not matter.

AGM

Sealed, spill-proof, better vibration resistance, charges slightly faster, and costs 40-80% more. Good where the battery is hard to access or must not leak.

Gel

Similar to AGM but requires lower charge voltages and is easy to ruin with a standard charger. Rarely the right choice now that LiFePO4 prices have fallen.

LiFePO4

Deep discharge without damage, 3,000-5,000 cycles, near-flat voltage curve, no maintenance, and 3-5× the cost up front. Wins on cost per cycle wherever the equipment gets regular use; loses where the battery is rarely cycled or sits in freezing conditions.

Mixing rule: never put a new battery in parallel with an old one, or two different chemistries on the same charger. The weaker battery sets the ceiling for the pair, and the mismatch accelerates failure in both.